12kV Eco-Friendly Gas Insulated Ring Main Unit (RMU)

12kV Eco-Friendly Gas Insulated Ring Main Unit (RMU)
Place of Origin:China
Product Details
Operating Temperaturerange: -25°C To +40°C
Insulationtype: Pure Air /nitrogen/eco-friendly Gas
Controltype: Manual/Electrical
Voltagerating: 12kV
Operating Mechanism: Spring Operating Mechanism
Currentrating: 630A/1250A
Mountingtype: Indoor/Outdoor
Dimensions: 600mm X 800mm X 1200mm
Numberoffeeders: 3
Product Description
Detailed Specifications & Features

Introducing our eco-friendly gas-insulated ring mani unit (RMU)

a next-generation switchgear that eliminates SF₆ . It uses a sustainable gas mixture - sush as clean air or fluoretone-based alternatives-with a global warming potential (GWP) of nearly zero.

Key Benefits & Applications:

It offers high reliability,compact design,and maintenance-free operation-ideal for secondary distribution,renewable integration,and industrial ues.

Advanced Features:

Fully sealed and corrosion-resistant,with robust safety interlocks,it supports both manual and automated actuation.

Full customization is available:

  • panel layout
  • busbar rating
  • fault interruption capacity
  • communication protocols(IEC 61850,Modbus,etc.)
  • cabinet size
  • environmental adaptationss
  • branding

A future-proof,compliant,and green switching solutions.

Technical Data Sheet
Item Unit Circuit Breaker Panel Load Switch Panel
Rated Voltage kV 12 12
Rated Frequency Hz 50 / 60 50 / 60
Rated Current A 630 / 1250 630
Interruption Medium / Vacuum /
Insulation Medium / Clean Air / Nitrogen (Note: Clean Air / Nitrogen means mixture of dry air and nitrogen, water content ≤15ppm) /
Rated Power Frequency Withstand Voltage (1min) — Phase-to-Earth / Phase-to-Phase kV 42 /
Rated Power Frequency Withstand Voltage (1min) — Across Breaking Gap kV 48 /
Rated Lightning Impulse Withstand Voltage — Phase-to-Earth / Phase-to-Phase kV 75 /
Rated Lightning Impulse Withstand Voltage — Across Breaking Gap kV 85 /
Short-time Withstand Current — Main Circuit kA/s 20/4 / 25/4 /
Short-time Withstand Current — Earthing Circuit kA/s 17.4/2 /
Rated Peak Withstand Current — Main Circuit kA 50 / 63 /
Rated Peak Withstand Current — Earthing Circuit kA 43.5 /
Rated Short-circuit Making Current (Peak) kA 50 / 63 /
Rated Short-circuit Breaking Current kA 20 / 25 /
Rated Short-circuit Breaking Operations (Class E2) times 30 /
Rated Operating Sequence of CB Module / O-0.3s-CO-180s-CO /
Rated Cable Charging Breaking Test / Class C2 /
Rated Earth Fault Breaking Current kA 17.4 /
Rated Active Load Breaking Current A / 630
Rated Ring Closing Breaking Current A / 630
Rated Cable Charging Breaking Test Current A / 10
5% Rated Active Load Breaking & Making Current A / 31.5
Rated Earthing Switch Making Operations times 5 (Note: The lower isolation earthing switch version of GHXGEN-12 series is 2 times) /
Loop Resistance μΩ ≤ 140 /
Rated Filling Gas Pressure (20℃ gauge) MPa 0.02 /
Minimum Operating Gas Pressure MPa 0 /
Mechanical Endurance – Circuit Breaker Load Switch times 10000 / 30000 /
Mechanical Endurance – Disconnector times 3000 / 6000 /
Mechanical Endurance – Earthing Switch times 3000 / 6000 /
Protection Class – Gas Tank / IP67 /
Protection Class – Enclosure / IP4X /
Rated Annual Leakage Rate % 0.01 /
Internal Arc Fault Withstand Capacity kA/s 20/0.5(20/1) / 25/0.5(25/1) /
Water Content Inside Gas Tank ppm ≤ 150 /

FAQ

Do you support customization? Yes, OEM/ODM is available. Custom dimensions, hole patterns, and plating thickness are all supported
What is the MOQ? MOQ varies by product type. Please contact us for details
Do you provide samples? Sample orders are accepted
What certifications do you have? ISO 9001,ISO 45001,ISO 14001 and GB (available upon request)|Meet the technical requirements of Indonesia PLN
What is your lead time? 15–30 days depending on order quantity
Message for quick reply
Related Products