logo
Jiangsu Changyun Intelligent Technology Co., Ltd
+86 18861115916

12kV Indoor High Voltage Sulfur SF6 Load Switch

12kV Indoor High Voltage Sulfur SF6 Load Switch
Place of Origin:CHINA
Brand Name:ChangYun
Certification:ISO9001
Model Number:FLN36-12D
Product Description
Detailed Specifications & Features
FLN36-12D 12kV SF₆ Load Break Switch for Medium Voltage RMU
Product Overview

The FLN36-12D 12kV SF₆ Load Break Switch is a high-performance medium voltage load break switch designed for safe and reliable switching in 12kV power distribution systems.

As a key component of SF₆ insulated Ring Main Units (RMU) and medium voltage switchgear, the FLN36-12D provides reliable load current switching, isolation, and earthing functions. It is widely used in utility distribution networks, industrial power systems, commercial buildings, renewable energy projects, and compact substations.

Featuring advanced SF₆ gas insulation and arc extinguishing technology, this indoor load break switch delivers excellent dielectric performance, high breaking capability, and long mechanical service life for modern medium voltage applications.


Key Features of FLN36-12D SF₆ Load Break Switch
1. Reliable SF₆ Gas Insulation

The FLN36-12D adopts sealed SF₆ gas insulation technology to ensure stable electrical performance and safe operation.

Benefits include:

  • Excellent insulation performance
  • Reliable arc extinguishing capability
  • Compact switchgear structure
  • Low maintenance requirements
  • Long operating lifetime

2. Designed for 12kV Medium Voltage Distribution

This 12kV load break switch is specially developed for medium voltage distribution applications with:

  • Rated voltage: 12kV
  • Rated current: 630A
  • Rated frequency: 50Hz
  • High short-time withstand capability

It is suitable for integration into:

  • 12kV RMU systems
  • Gas insulated switchgear (GIS)
  • Medium voltage switchgear panels
  • Compact substations

3. Three-Position Switching Mechanism

The FLN36-12D provides a safe three-position operation:

  • ON (Load switch closed)
  • OFF (Load switch open)
  • Earth (Earthing position)

The mechanical interlocking design prevents incorrect operation and improves personnel safety during maintenance and operation.


4. Compact Design for RMU Applications

With its compact structure and reliable insulation system, the FLN36-12D is an ideal RMU load break switch solution.

It helps manufacturers and system integrators achieve:

  • Smaller switchgear dimensions
  • Flexible configuration
  • Reliable medium voltage switching performance
  • Easy integration into RMU assemblies

Technical Specifications
Item Specification
Product Type SF₆ Load Break Switch
Rated Voltage 12kV
Rated Frequency 50Hz
Rated Current 630A
Power Frequency Withstand Voltage 42/48kV
Lightning Impulse Withstand Voltage 75/85kV
Rated Short-Time Withstand Current 20kA
Rated Peak Withstand Current 50kA
Short-Circuit Closing Current 50kA
Cable Charging Breaking Current 10A
SF₆ Gas Pressure 0.4 bar
Mechanical Life 5000 operations

Applications of 12kV SF₆ Load Break Switch

The FLN36-12D medium voltage load break switch is widely applied in:

Utility Power Distribution

Used in 12kV distribution networks for safe switching and isolation.

Ring Main Units (RMU)

Provides reliable switching functions for SF₆ insulated RMU systems.

Industrial Power Systems

Suitable for factories, industrial parks, and large electrical facilities.

Renewable Energy Projects

Applied in solar farms, wind power plants, and energy storage systems.

Commercial Buildings

Supports safe medium voltage power distribution for large buildings and infrastructure.


FLN36-12D vs Traditional MV Switches
Feature FLN36-12D
Voltage Level 12kV
Insulation Medium SF₆ Gas
Switching Function Load Switching + Earthing
Installation Indoor
Application RMU & MV Switchgear
Maintenance Low Maintenance Design

Why Choose Changyun FLN36-12D Load Break Switch?
  • Professional manufacturer of medium voltage switchgear components
  • Suitable for RMU and MV switchgear integration
  • Reliable SF₆ insulation and arc extinguishing technology
  • High electrical and mechanical performance
  • OEM/ODM customization available
  • Supports global MV distribution projects

FAQ
What is a 12kV SF₆ Load Break Switch?

A 12kV SF₆ load break switch is a medium voltage switching device that uses SF₆ gas insulation and arc extinguishing technology to safely switch load currents in 12kV distribution systems.


What is the difference between a load break switch and a circuit breaker?

A load break switch is mainly designed for switching normal load currents and isolation, while a circuit breaker provides protection by interrupting fault currents.


Can FLN36-12D be used in RMU?

Yes. The FLN36-12D is commonly integrated into SF₆ insulated RMU and medium voltage switchgear systems.


Does Changyun provide OEM load break switches?

Yes. Changyun supports OEM and customized solutions for RMU manufacturers, panel builders, and electrical equipment suppliers.

Message for quick reply
Related Products